
Slide Mounting Media
- (30)
- (1)
- (1)
- (1)
- (4)
- (2)
- (1)
- (1)
- (2)
- (1)
- (16)
- (2)
- (1)
- (1)
- (3)
- (2)
- (1)
- (3)
- (1)
- (2)
- (8)
- (5)
- (2)
- (17)
- (5)
- (2)
- (1)
- (1)
- (1)
- (2)
- (2)
- (3)
- (3)
- (2)
- (9)
- (1)
- (1)
- (2)
- (1)
- (16)
- (2)
- (9)
- (12)
- (1)
- (2)
- (23)
- (1)
- (9)
- (2)
Filtered Search Results

Perkin Elmer US LLC Adhesive Film Mount - Qty. 100
PerkinElmer offers a variety of sample holders and film mounts that are convenient, easy-to-use, and economical.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Fluoro-Gel Mounting Medium with TES Buffer 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Fluoro-Gel is a water based mounting medium designed for the permanent mounting of fluorescent stained tissues, which may either be damaged or soluble in organic solvents, such as xylene or toluene. This unique formula prevents rapid photo-bleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa Fluoro 488, Alexa Fluoro 594, Green Fluorescent Protein (GFP), Tetramethylyrhodamine, Redox, Phycoerythrin (RP-E), Phyocyanin (PC), and Allophycocyanin (APC).
The fluorescence is retained during prolonged storage at 4 degree C in the dark. Application: Immunofluorescence, confocal microscope.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution AF87, Glycerol Free, Non Hardening 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. Immersion oil having a refractive index of 1.52 and contains an antifadent.
Material: Glycerol Free
Type: Non Hardening

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Limonene-Mount (Substitute for BioMeda Clarion Mount) 250 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
This mounting medium is made with limonene, a natural product from orange peels. It preserves tissues and cell smears that can be dehydrated with organic solvents in immunohistochemistry, e.g. DAB and DAB with nickel or cobalt. Our Limonene-Mount also works well with alkaline phosphatase chromogens, and organic solvent resistant Supper Fast Red. It is also a good choice for mounting H and E stained slides. Application: Mounting tissues and cell smears.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution AF2, Glycerol Based, Non Hardening 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. A glycerol solution contains an amine antifadent. Select buffer.
Material: Glycerol Based
Type: Non Hardening

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Citifluor™ Mountant Solution AF1, Glycerol Based, Non Hardening 100 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Citifluor mounting medium for immunofluorescence is designed to reduce the fading of the fluorescence of dyes used for labeling biological specimens. In the technique of fluorescence microscopy, the fluorescence is stimulated by high intensity UV and/or visible light. Absorption of the light populates an excited state of the dye (usually a singlet state) and this leads to fluorescence. However, the excited state of the dye may undergo chemical reaction, which leads to destruction as evidenced by the fading of the fluorescence and consequent loss of the image. A glycerol-PBS solution contains an amine antifadent.
Material: Glycerol Based
Type: Non Hardening

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Beckman Coulter Kit Mounting Cytomat 10C
Kit Mounting Cytomat 10C

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS CitraMount Mountant 500 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
This butyl acetate and acrylic resin mixture is the first mounting medium developed for coverslipping directly from d-limonene based clearants. Superior results are also with xylene. CitraMount medium is recommended for manual coversliping only as it may cause damage to the valves of automated coverslippers. Clear seal has a drying time of less than 24 hours. Refractive index is 1.42 and Viscosity is 90 cP.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Technovit Mounting Press
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
For use with Technovit resins. ..

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Biocare Medical, LLC Fluoro Care Anti-Fade Mountant - 10 ml
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Fluoro Care Anti-Fade Mountant is an innovative, liquid-based, anti-fade mounting medium designed especially for the permanent preservation of fluorescent specimens. Fluoro Care is to be used with tissue sections stained with a multitude of fluorescent dyes. Fluoro Care is compatible with DyLightTM Fluors, Alexa Fluors®, fluorescein, rhodamine, Texas Red and stained specimens.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Silver Conductive Adhesive 478ss 15 GR
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Our adhesive 478SS is a conductive, silver-based polymer which is used for thick film coatings where liquid silver is not an option. Once cured, it offers a very high Tg (glass transition temperature) 153 degree F (67 degree C) to prevent blocking, and offers superior adhesion to polyester film. Adhesive 478SS can be cured at 200 degree F (93 degree C) within 15 minutes. Higher temperatures will reduce the time needed to achieve a final cure.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences LR White Resin, Medium, Uncatalyzed 500 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
A very low viscosity (8cps), non-toxic resin, suitable for both Light and Electron Microscopy. LR White is a polar monomer polyhydroxylated acromatic acrylic resin. It can be cured by heat or by UV light. Sections of polymerized LR White resin are hydrophilic. This character allows immuno-cytochemistry reagents to easily penetrate into the sections and etching of the sections is not necessary (etching sections will effect delicate tissue antigens). LR White sections also show minimal non-specific staining. Its low viscosity makes it ideal for infiltrating decalcified bone and teeth as well as plant tissues.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences LR White Resin, Hard, Uncatalyzed 500 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
A very low viscosity (8cps), non-toxic resin, suitable for both Light and Electron Microscopy. LR White is a polar monomer polyhydroxylated acromatic acrylic resin. It can be cured by heat or by UV light. Sections of polymerized LR White resin are hydrophilic. This character allows immuno-cytochemistry reagents to easily penetrate into the sections and etching of the sections is not necessary (etching sections will effect delicate tissue antigens). LR White sections also show minimal non-specific staining. Its low viscosity makes it ideal for infiltrating decalcified bone and teeth as well as plant tissues.

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Entellan Rapid Mounting Media 500 ML
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Entellan is a rapid mounting media for microscopy. It can be used for long life preparations, without bubble formation at high ambient temperatures. Also for all dehydrated microscopic preparations. Cure time is 20 minutes at room temperature. It is colorless with an acid number less than 2.50 and a R.I. ND20 approx 1.49-1.5. (Contains xylene).

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMbed 812, 450ml
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
EMbed 812 has the same characteristics as Epon 812, physically, and provides the same results in preservation, handling, curing and sectioning. EMbed 812 may cause etching on selected plastics. All formulas for mixing and using Epon 812 can be applied to EMbed 812

Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More